Physical Data - Indoor Unit

Indoor Unit CO RAS-M10GDCV-E RAS-M13GDCV-E RAS-M16GDCV-E
HP RAS-M10GDV-E RAS-M13GDV-E RAS-M16GDV-E
Air Flow (h/l) m3/h - l/s CO 720/400 - 200/111 780/428 - 217/119 780/428 - 217/119
Sound Pressure Level (h/l) dB(A) CO 31/23 32/24 33/25
Sound Power Level dB(A) CO 44/36 45/37 46/38
Air Flow (h/l) m3/h - l/s HP 720/450 - 200/111 780/428 - 217/119 780/428 - 217/119
Sound Pressure Level (h/l) dB(A) HP 32/24 33/25 34/26
Sound Power Level dB(A) HP 45/37 46/33 47/34
Dimensions (h x w x d) mm 230 x 750 x 440 230 x 750 x 440 230 x 750 x 440
Weight kg 19.00 19.00 19.00
Flare Connections (gas - liquid) 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
External Static Pressure (stand/upper limit) Pa 35,3/55,9 41,2/67,3 41,2/63,7