Physical data

Indoor unit RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E
Air Flow (H/L) m3/h - l/s 690/522 - 192/145 690/522 - 192/145 780/582 - 217/162
Sound pressure level (H-M-L)* dB(A) 39-36-33 39-36-33 45-40-36
Sound power level (H-M-L)* dB(A) 54-51-48 54-51-48 60-55-51
Dimensions (HxWxD) mm 210 x 845 x 645 210 x 845 x 645 210 x 845 x 645
Weight kg 22.00 22 22
External static pressure (stand/upper limit) Pa 5/24 5/24 4/24
C = cooling mode
H = heating mode
*bottom air inlet
DT-E : 220-1-50/60Hz