Performances with SDI

Outdoor unit RAV-SP404ATP-E RAV-SP454ATP-E RAV-SP564ATP-E
Indoor unit (Slim duct) RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E
Cooling capacity kW 3,6 4,0 5,0
Cooling range (min. - max.) kW 1,5 - 4,0 1,5 - 4,5 1,2 - 5,6
Power input (min. - rated - max.) kW C 0,37 - 1,03 - 1,25 0,37 - 1,2 - 1,49 0,21 - 1,56 - 2,29
EER 3,50 3,33 3,21
SEER 5,11 5,01 5,1
Energy efficiency class C A B A
Seasonal electricity consumption kWh/a C 246.35 279.53 343.13
Heating capacity kW 4,0 4,5 5,6
Heating range (min. - max.) kW 1,5 - 5,0 1,5 - 5,6 0,9 - 7,4
Power input (min. - rated - max.) kW H 0,37 - 1,00 - 2,20 0,37 - 1,15 - 2,30 0,17 - 1,44 - 2,37
COP W/W 4,00 3,91 3,89
SCOP 3,9 3,9 3,83
Energy efficiency class H A A A
Seasonal electricity consumption kWh/a H 1364.05 1364.05 1975.15
C = cooling mode
H = heating mode
*bottom air inlet
The specification may be subject to change without notice for purpose of improvement.